Deenergized tap changer, type dtu application, installation. Advantages of the vucl onload tap changer revision. Abb s portfolio includes bridging, linear and rotary options, with ratings up to 4,000 a and 1,050 kv bil. Voltage regulation by transformer offload tap changer, on. English pdf instruction type dtu deenergized tap changer application, installation.
Abb offers a full range of products for both high voltage and low voltage regulation. A single source for all parts and services modern tap changer designs. Technical guide type vrltc load tap changer abb group. If prefered otherwise, please select from the following option. This is based on changing the turns ratio of a transformer, hence the voltage in the secondary circuit is varied. Onload tapchangers for power transformers a technical. Control of transformers tap changer is the most popular form of voltage control at all voltage levels in a power system. Tap changers for power transformers, product guide revision. The standard number of positions is five with seven positions available in certain winding configurations. Ghanim putrus, edward bentley, in electric renewable energy systems, 2016. A deenergized tap changer is a switch, which is connected to the winding taps of the transformer. The deenergized tap changer is usually installed into the high voltage circuit of the transformer and, most of the time, it is used to adjust the primary voltage of the transformer within a 5 percent range in four steps.
Advantages of the vucl onload tap changer document native title. The dtu tap changer uses silver plated moving contacts to bridge between two of the copper stationary contacts to make a tap connection. Abb offers rotary deenergized tap changer type dpc for liquidfilled power transformer applications. For tap changers with a different number of positions, please contact abb after filling out this order data sheet. From modular bul and versatile bue for intank onload tap changers to the digitally controlled smd with integrated tap logic monitoring system tlms for the type vrltc tap changer. It is most commonly available as a 5position device. The type dtw tap changer is a modular, bridgingtype zigzag tap changer with an external operating mechanism. The type dtu is a modular, linearaction, bridgingtype, deenergized tap changer. Uc technical guide, onload tap changers document native title. Space saving design and highclass material assure the best performance and reliability. The type dtw tap changer is made up of individual tap decks one or more per phase.
Kdv um 24 kv, ir 300 a iec deenergized tapchangers and. For accessories available for the tap changer, consult abb. The type dtu deenergized tap changer is one of a family of. The type dtw deenergized tap changer is a versatile tapchanging switch, which is. Onload tapchangers, type uze and uzf, with motordrive. Operation of the tap changer is via a manual gearbox mounted on the exterior surface of the transformers. The tap changer is a modular design, which allows a wide variety of configurations to suit the needs of the transformer designer. Tap changers for power transformers, product guide document native title. Supply authorities are under obligation to their customers to maintain the supply voltage between certain limits. Abb offers low voltage rotary type deenergized tapchangers type kdv for. Dtu the dtu is a modular, linearaction, bridgingtype, tap changer design available with current rating of up to 500 a per deck and up to 650 kv bil. Tapchanger services for transformers english pdf brochure.
At um 300 kv, ir 650 a iec deenergized tapchangers and. Our tap changers are paired with robust, dependable motor drives that are configurable to meet a wide range of environmental conditions and customer specifications. Abb this adjustment may be made by an onload tap changer, or by means of an offcircuit tap changer, or by the selection of bolted link positions with the. Onload tap changers type ubb the ubb is a selector switch type of onload tap changer.
Tap changer maintenance intervals are usually dictated by the number of taps number of open and close operations, or, by the period of time in operation e. Multiple deck arrangements make our designs the most compact deenergized tap changers on the market. Afwf air forcedwater forced cooling by hydrocoolers. Vacuum onload tapchangers tapchangers and switches. The method, as applied to tap changers, is described in the first part, and its application to circuit breakers is described in the second part. Vacuum cast coil dry type distribution transformers. Vibroacoustic testing applied on tap changers and circuit.
For seriesparallel switches, please use the order data sheet 1zua4643204. We have a proven solution to your needs abb vacuum cast coil dry transformer for marine applications. Abb deenergized tapchangers are the preferred solution of transformer. Transformer voltage regulation offload tap changer, onload tap changer and avr photo credit. The tap changer tank can be bolted standard or welded to the transformer tank. Abb offers a comprehensive portfolio of onload tapchangers both the. Dtu deenergized tap changer the type dtu is a modular, linearaction, bridgingtype, deenergized tap changer design available with current rating of up to 500 a per deck and up to 650 kv bil. When the tap changer is moved from one position to another, the amount of the tap winding connected into the circuit is changed.
Abb library is a web tool for searching for documents related to abb products. More detailed information about the type dtu tap changer can be. This is a worksheet that allows the user to select options when ordering a dtu tap changer. Function principle of onload tap changers presented by mr, world market leader in oltcs. Abb offers low voltage rotary type deenergized tap changers type kdv for liquidfilled distribution transformers, which combine electrical and mechanical reliability with versatility of application and ease of connection to transformer tapping leads. Strong cylinder structure and design based on existing abb mature onload tap changer technology ensure high reliability and performance. Tapchangers for power transformers, product guide english pdf product guide. Abb tres is able to provide the right combination of custom engineering and field expertise to design, procure, and install a replacement ltc or to retrofit an existing ltc.
Language options english french please select one of the following options. Abb library could not identify a unique document based on the available parameters. A nonstandard tank can also be ordered, but to a higher price and with a longer delivery time than the standard tank. When the tap changer operates, arcing occurs in the tap changer. Other configurations are available or can be designed. Show properties create link bookmark latest revision create link bookmark revision d find related documents close this window. Abb library is a web tool for searching for documents related to abb products and services. The type dtw deenergized tap changer is a versatile tap changing switch, which is mounted inside the main transformer compartment attached to the cleat and lead structure of the transformer.
The load current must never be interrupted during a tap change. Deenergized tap changers abb has 2 different power class deenergized tap changers available to fit a wide variety of transformer manufacturer needs. The type dtu deenergized tap changer is one of a family of abb tap changers for power transformers. It is designed for mounting inside of the transformer tank, but many of the features and benefits our customers appreciate from our uz ontank technology. English pdf data sheet dtu tap changer order data sheet english pdf data sheet deenergized tap changer type dpc order datasheet english, chinese pdf data sheet. Tapchangers and switches transformer insulation and. This document contains instructions and maintenance information for the vrltc tap changer. The ltc meets all of the required specifications according to ieee c57. This order data sheet is for 5 position dtu tap changers. These switches select the physical tap position on the transformer winding and, because of their construction, cannot and must not make or break the load current 2.
Assembly for dtw english pdf drawing mounting boss details for dtw and dtu english pdf drawing. Abb high voltage linear type deenergized tap changers type at represent a perfect solution for applications in which a low value of partial discharges is required. The standard number of positions is five with seven positions available in. Advantages of the ucg onload tap changer document native title. Selecting tap changers for alternative insulation fluids. A tap changer is a device fitted to power transformers for regulation of the output voltage to required levels. Deenergized tapchangers and switches abb deenergized tap changers are the preferred solution of transformer manufacturers worldwide thanks to their simplicity and ease of installation. Based on this extensive knowhow the company has developed a system consisting of carefully matched safety devices. Abb tap changers are paired with robust, dependable motor drives that are configurable to meet a wide range of customer specifications. Upgrading of onload tap changer types ucgucl to vacuum types vucgvucl. This is normally achieved by changing the ratios of the transformers on the system by altering the number of turns in one winding of the appropriate transformers. Advantages of the uz onload tap changer document native title. What is a transformer tap changer engineering tutorial.
90 459 21 993 1101 1385 816 958 542 309 1257 1467 156 174 1515 942 96 81 1256 1431 407 808 684 796 205 10 876 460 166 1152 126 1485 927 969 685 23 1552 776 15 403 718 922 1154 976 1091 1368 845 1125 514 996